Air Conditioning

Air Conditioning Installation & Servicing

Central plant, ducted and VRV/VRF systems designed, installed and maintained by F-Gas qualified engineers.

Which air conditioning systems does Cool Stream install?

Cool Stream designs, installs and maintains central plant, ducted and VRV/VRF air conditioning, including ceiling cassette units, for offices, restaurants, retail and industrial sites across the UK. Systems use R410A refrigerant, can use inverter technology to cut energy use by up to 30%, and are pressure tested to BS EN378 by F-Gas qualified engineers.

Last updated

Total environment control

Consistent conditions, whatever the weather

Air conditioning systems provide and maintain internal air conditions at a pre-determined level, regardless of time of year, season or external atmospheric conditions. Central plant or ducted systems combined with heating, humidification or dehumidification, filtration and heat recovery can achieve almost any pre-set internal condition — ensuring the optimum environment for your application or process, with complete control over distribution and several control strategies available.

VRV/VRF systems provide cooling and heating for large offices and less complex areas, with multiple ceiling-mounted cassette or ceiling-concealed fan units served by a single external condensing unit.

Air conditioning refrigerant pipework installation
System features

Air conditioning systems, fully featured

Full Climate Control

Cooling, heating, humidification and de-humidification in one system.

Comfort Cooling & Heating

Consistent, comfortable conditions all year round.

Free Cooling

Uses external air to save energy whenever conditions allow.

Heat Recovery

Recovers energy from extract air to reduce running costs.

Intelligent Controls

Maximises system efficiency and optimises energy use.

VRV / VRF Systems

Multiple indoor units from a single outdoor condenser.

Air conditioning unit installed in a modern room
Keeping systems running

Preventative maintenance, tailored to you

Cool Stream Ventilation employs highly skilled engineers to ensure air conditioning and ventilation equipment is maintained to the highest possible standards. Our preventative maintenance programmes are tailored closely to the requirements of our clients in terms of environment, type of equipment and budget. We operate across every market sector and maintain every type of air conditioning system, including cassettes, chillers, air handling units and close control systems — working with the main suppliers in the industry to source spares quickly and at competitive prices.

F-Gas Regulation

Compliant by design, not by accident

Our engineers are qualified to current industry standards to ensure air conditioning plant is professionally monitored and maintained, and that our clients comply with the F-Gas Regulation. Under the regulation, users carry the legal liability to ensure refrigerant does not leak and is recovered properly during servicing and replacement, in order to limit refrigerant emissions.

We implement all measures in accordance with the best available techniques to reduce the relative loss of refrigerant to below a maximum of 5%. Used refrigerant not intended for re-use is dealt with as waste for safe disposal. As a contractor we know that fixing leaks is just treating symptoms — we advise on future refrigerant strategies and carry out full system analysis to protect customers against equipment breakdowns, regulatory penalties and rising energy costs.

  • Refrigerant loss kept below 5% maximum
  • Leak detection from day one of installation
  • All installations pressure-tested to BS EN378
  • Competitive R22 replacement programmes where systems are beyond economical repair

Choosing the right type of commercial air conditioning

Commercial air conditioning is not one product. The right system depends on the size of the space, how many separate zones need different temperatures, and how much heat the building gains.

SystemBest forThings to weigh up
Single splitOne room or a small shopSimple and low cost, but one indoor unit per outdoor unit
Multi-splitA few rooms sharing one outdoor unitFewer outdoor units on the wall or roof; limited number of indoor units
VRV / VRFOffices, restaurants, hotels and larger buildings with many zonesMany indoor units on one system; some can heat and cool different zones at once
DuctedOpen-plan areas where ceiling cassettes or wall units are unwelcomeConcealed units; needs ceiling void space for ductwork
Central plant (chilled water)Large or complex buildingsChillers, pumps and air handling units; higher complexity and maintenance
Close controlIT rooms and other rooms needing tight temperature and humidityDesigned for continuous, precise cooling

We design and install central plant and ducted systems with heating, humidification or dehumidification, filtration and heat recovery, plus VRV/VRF systems with ceiling cassette or concealed fan units. For a side-by-side comparison read VRF or split system air conditioning: which is right for a commercial building?.

How a system is sized

Cooling load is the amount of heat that has to be removed to keep a space comfortable. It comes from four main places: heat arriving through the building (sun on glazing, roofs and walls), people, lighting and equipment, and fresh air brought in for ventilation. A shop with a big south-facing window and a busy till area has a very different load from an interior office of the same floor area.

An undersized system never keeps up on a hot day. An oversized one cycles on and off, controls humidity poorly and wastes energy. That is why we survey and calculate rather than quote from floor area alone, and why the type of use (restaurant, office, retail, server room) matters to the design.

Restaurants and commercial kitchens

Air conditioning in a restaurant has to work with ventilation, not against it. Dining areas lose cool air to the kitchen extraction, and strong draughts across the pass or line can disrupt the capture of cooking fumes. HSE advises that where cooler air is needed in a kitchen it can be provided by balanced make-up air, by air conditioning, or by fixed fans that do not affect the efficiency of extraction. Local free-standing fans, by contrast, can disturb extraction. We design the air conditioning and the kitchen ventilation together so they do not fight each other. See our guide to restaurant air conditioning.

Energy efficiency

Modern systems use inverter compressors that match their speed to the load in the room instead of switching fully on and off. By matching compressor speeds to the cooling or heating load of a room, up to a 30% reduction in energy consumption can be achieved. Other savings come from good controls (schedules, set-back, occupancy sensing), correct zoning, heat recovery where simultaneous heating and cooling is needed, and regular maintenance, since dirty coils and filters make plant work harder. Our environment page explains our approach to R410A refrigerant and energy.

Refrigerants and F-gas rules

Most commercial air conditioning contains fluorinated gases (F-gases). Under GOV.UK's F-gas guidance, operators of equipment above set thresholds must have it leak-checked by a suitably certified person at set intervals, and must repair leaks as soon as possible. For example, GOV.UK's guidance sets leak-check intervals of every 12 months for equipment containing at least 5 tonnes of CO2 equivalent, every 6 months from 50 tonnes, and every 3 months from 500 tonnes, with intervals doubled where a leak detection system is fitted. Check the current GOV.UK guidance because thresholds and wording can change. Older systems that use R22 refrigerant can no longer be serviced with R22, so replacement is often the sensible route; we install replacement systems at competitive rates with minimum disruption. Our F-Gas guide for commercial air conditioning explains what operators should do.

Installation, commissioning and handover

We survey the building, agree the design and system layout, install indoor and outdoor units and pipework, test the pipework and system to BS EN 378, and commission before hand-over. Work is planned to minimise disruption, which matters in trading restaurants, offices and shops. After hand-over we offer planned maintenance so the plant stays efficient and compliant.

What to ask before you buy

  1. How was the cooling load calculated?
  2. Which refrigerant does the system use, and how much is in the circuit?
  3. Who will carry out the leak checks, and are they suitably certified?
  4. What will the running costs look like, and how are controls set up?
  5. Where do indoor and outdoor units go, and how will noise and condensate be handled?
  6. What maintenance does the manufacturer require to keep the warranty valid?
FAQs

Frequently asked questions

What types of air conditioning do you install?

Central plant and ducted systems with heating, humidification or dehumidification, filtration and heat recovery, plus VRV/VRF systems with ceiling cassette or concealed fan units.

Are you F-Gas compliant?

Our engineers are qualified to current industry standards so that your plant is professionally monitored and maintained in line with the F-Gas Regulation, keeping relative refrigerant loss below a maximum of 5%.

How much energy can inverter air conditioning save?

By matching compressor speeds to the cooling or heating load of a room, up to a 30% reduction in energy consumption can be achieved.

Can you replace old R22 systems?

Yes. Where systems are beyond economical repair, or you are looking to replace equipment using R22 refrigerant, we provide installations at competitive rates with minimum disruption.

What is the best type of air conditioning for a restaurant?

It depends on the layout. Many restaurants use ceiling cassette or ducted units on a VRV/VRF or multi-split system so dining areas can be controlled independently, designed together with the kitchen ventilation.

What is the difference between VRV and VRF?

They are two names for the same technology. VRV (variable refrigerant volume) is Daikin's trade name and VRF (variable refrigerant flow) is the generic term: one outdoor unit serving many indoor units with refrigerant flow matched to demand.

How often does commercial air conditioning need servicing?

At least annually is common practice, and F-gas leak checks are required at intervals set by the refrigerant charge. Busy sites often benefit from a planned maintenance schedule more frequent than the legal minimum.

What are the F-gas leak check intervals?

Under GOV.UK guidance, every 12 months for equipment of at least 5 tonnes CO2 equivalent, every 6 months from 50 tonnes and every 3 months from 500 tonnes, doubled where leak detection is fitted. Check current GOV.UK guidance for your equipment.

Can I still use R22 air conditioning?

Existing R22 equipment may still run, but R22 can no longer be used to top up or service it. If it leaks, replacement is often more practical than repair.

How much energy can inverter air conditioning save?

By matching compressor speeds to the load, up to a 30% reduction in energy consumption can be achieved.

Do you design air conditioning for server rooms?

We maintain close control systems and design central plant and ducted systems. Tell us about the room and its load and we will advise.

Can air conditioning be installed while the business is trading?

Usually yes. We plan installation to minimise disruption, working out of hours where needed.

Does air conditioning also provide fresh air?

Not by itself. Most split and VRF indoor units recirculate room air. Fresh air comes from a separate ventilation system, often with heat recovery.

Do you install air conditioning across the UK?

Yes. We survey, design, install and maintain for customers across the UK. See our service areas or call 07759 696007.

Areas we serve

Installed and maintained across the UK

Wherever your site is, we survey, design, manufacture and install. Find your nearest area, or call 07759 696007.

Book an air conditioning survey, install or service.

F-Gas qualified engineers, competitive rates and minimum disruption to your site.