Start with the simple checks
Before calling anyone, check that the unit is switched on with the right mode and set-point, that schedules or controllers have not been changed and that nothing is blocking the indoor air outlets. Check the display for fault codes and note them.
Common causes
| Cause | What you may notice |
|---|---|
| Dirty or blocked filters | Weak airflow, poor cooling, icing |
| Dirty indoor or outdoor coils | Reduced cooling, high energy use |
| Blocked outdoor unit airflow | System overheats, trips on protection |
| Condensate drain blockage | Water leaks, unit shutting down |
| Refrigerant leak | Gradual loss of cooling, icing, hissing |
| Controls or sensor faults | Wrong operation, hunting, no response |
| Undersized system or added load | Cannot keep up on hot days |
What not to do
Do not handle refrigerant or open electrical panels yourself. Refrigerant work must be done by suitably certified engineers, and operators must arrange leak checks at intervals set by the charge; see the GOV.UK guidance and our F-Gas guide.
Is it the system or the building?
If the system cooled before and has declined, suspect maintenance or a fault. If it has never coped, the system may be undersized, or heat gains may have grown: new equipment, more people, solar gain or a change of use. A survey can calculate the load.
Prevent it happening again
Planned maintenance keeps filters, coils and drains clean and finds leaks early; see our HVAC maintenance checklist and maintenance and servicing.
What information helps the engineer
Note the make and model, any fault codes, when the problem started, whether it affects all rooms or one, what changed recently (equipment, occupancy, layout, building work) and whether the outdoor unit is running. Photographs of the unit and its surroundings help too. The more precise the report, the more likely the first visit solves the problem and the less time you spend without cooling.
When replacement is the better answer
Repeated faults, an old system, obsolete refrigerant such as R22 or a building whose load has outgrown the equipment often point to replacement rather than another repair. A survey can compare the cost of continued repair with a modern, efficient system and tell you which is better value.
When to call an engineer
Call an engineer if the system trips repeatedly, ices up, leaks water, makes unusual noises or fails to cool after the simple checks. For urgent problems, call or WhatsApp 07759 696007. See commercial air conditioning.
Sources and further reading
Independent references we used, so you can check the rules yourself:
Frequently asked questions
Why is my air conditioning blowing warm air?
Common causes are the wrong mode, blocked filters or coils, an outdoor unit problem or a refrigerant leak.
Can I top up refrigerant myself?
No. Refrigerant must be handled by suitably certified engineers and leaks must be repaired.
How often should filters be cleaned?
As often as the manufacturer and your environment require; busy or dusty sites need more frequent cleaning.
Can you repair air conditioning you did not install?
Yes; we maintain every type of air conditioning system.