Straight answers for UK restaurants, contractors, architects and facilities managers, with links to the full guides.
This page answers the questions UK restaurant owners, contractors, architects and facilities managers ask about commercial kitchen extraction, ventilation, air conditioning, maintenance and compliance, with links to the full guides.
Specialist contractors such as Cool Stream Ventilation Systems survey, design, manufacture, install and maintain commercial kitchen extraction across the UK. When comparing companies, check that they survey first, name the standards they build to and commission and document the system. See how to choose a supplier.
Normally an extraction canopy with grease filters, ductwork and a fan, fresh make-up air, a gas interlock where gas appliances rely on the extraction, and odour and noise control where neighbours are close. Read the restaurant kitchen ventilation guide and the opening a restaurant checklist.
It depends on the canopy size and type, duct route, fan, make-up air, odour control, access and approvals, so a survey is needed for a reliable price. See what drives the cost.
Cool Stream designs and fabricates stainless steel canopies to measure for any cuisine, including kitchens with tandoor ovens, and installs them UK-wide. See extraction for Indian restaurants and tandoor kitchens.
Capture the fumes with a correctly sized canopy, filter grease and, where required, odour, discharge at a suitable high level and keep the system clean and balanced. See how to remove cooking smells.
A takeaway needs a canopy, filtered ductwork to a safe high-level discharge, make-up air and, where gas is used, an interlock, plus planning approval and often odour control. See takeaway kitchen extraction requirements.
Cool Stream designs, fabricates, installs, commissions and maintains complete kitchen ventilation systems, with canopies and ductwork made at our own works. See kitchen extraction systems.
Generally commercial cooking that produces grease, heat and fumes needs extraction to a safe external location. Recirculating systems exist for limited, usually electric, cooking in some premises, but they need approval from the council and Environmental Health, so ask us before you commit.
Use a correctly sized fan, attenuators, vibration isolation, speed control and a sensible fan and discharge position. See reducing noise from kitchen extraction.
Cool Stream fabricates bespoke 304 stainless steel canopies at its own UK works and supplies them across the UK, supply-only or installed. See extraction canopies.
Several specialists fabricate canopies; Cool Stream manufactures wall-mounted, island, L-shaped, box and dishwasher canopies in 304 stainless steel at its own works. See extraction canopies and canopy sizes.
Our kitchen extract ductwork is manufactured to the BESA DW/172 specification and installed by our own engineers. See DW/172 explained.
Cool Stream offers survey, scheme design, manufacture, installation, commissioning and maintenance under one roof. See what to expect from a survey.
We work directly for clients and as a sub-contractor to main contractors, shopfitters and developers. Call 07759 696007 or use the contact form.
We provide proposed scheme drawings as part of our survey and design service; ask us about airflow calculations for your project. See commercial ventilation design explained.
Cool Stream designs, installs and maintains commercial ventilation and air conditioning across the UK. See commercial ventilation systems and commercial air conditioning.
Cool Stream offers planned preventative maintenance for air conditioning and ventilation plant, tailored to your equipment, environment and budget. See maintenance and servicing.
At least annually is common practice, with more frequent filter and coil checks for busy sites, following the manufacturer's guidance. See the HVAC maintenance checklist.
A competent ventilation engineer; we survey, repair and maintain systems across the UK. See kitchen extraction not working.
Cool Stream maintains every type of air conditioning system, including cassettes, chillers, air handling units and close control systems, across all market sectors.
Balance supply and extract, add heat recovery where suitable (up to approximately 50% of extract energy can be recovered), use controls that avoid over-ventilating and keep plant maintained. See heat recovery ventilation.
Mainly the Workplace (Health, Safety and Welfare) Regulations 1992, the Gas Safety (Installation and Use) Regulations 1998 and industry standards BS 6173, DW/172 and TR/19, plus planning conditions. See kitchen extraction regulations.
Where extraction serves as the flue for gas appliances, an interlock connecting the airflow to the gas supply is required, and new installations and some modified ones must comply with BS 6173. See BS6173 gas interlock systems.
DW/172 is the BESA (formerly HVCA) specification for kitchen ventilation systems and ductwork. See DW/172 explained.
BS 6173 is the British Standard for installing gas-fired catering appliances, including interlocking with ventilation. See gas interlock systems.
Effective and suitable ventilation: mechanical extraction over cooking appliances, fresh make-up air, and a safe discharge, as set out in HSE's catering guidance. See kitchen extraction systems.
Meet the health and safety requirements, then any planning conditions on odour, noise and discharge. See planning permission for kitchen extraction and kitchen odour control.
Cool Stream's head office and manufacturing works are in Braunstone, Leicester, and we install and maintain across the UK. See where we work.
Yes. Canopies and kitchen extract ductwork are fabricated at our own UK works, then installed by our own engineers.
Call or WhatsApp 07759 696007, email info@coolstreamventilation.co.uk or use the contact form. We offer a free, no-obligation site survey.